Metrologic MS7620 Guía de usuario

Busca en linea o descarga Guía de usuario para Lectores De Códigos De Barras Metrologic MS7620. Metrologic MS7620 User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 60
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
METROLOGIC INSTRUMENTS, INC.
MS7600 Horizon
Series
Installation and User’s Guide
Vista de pagina 0
1 2 3 4 5 6 ... 59 60

Indice de contenidos

Pagina 1 - Installation and User’s Guide

METROLOGIC INSTRUMENTS, INC.MS7600 Horizon™ SeriesInstallation and User’s Guide

Pagina 2

6MOUNTING THE MS7600 SERIESOPTION B: Free Hanging SupportFigure 8: Package Flow (right)Figure 9: Specifications for free hanging support.Figure 10: In

Pagina 3 - LOCATIONS

7MOUNTING THE MS7600 SERIESOPTION C: Trim Ring (MLPN 46-46641, Additional Purchase)Figure 11: Counter Top Opening for Trim Ring (MLPN 46-46641)Figure

Pagina 4 - TABLE OF CONTENTS

8Figure 14: Keyboard WedgeInterfaces INSTALLATION FOR KEYBOARD WEDGE INTERFACE1. Turn off the host system.2. Disconnect the keyboard from the host.3

Pagina 5 - INTRODUCTION

9Figure 15: Stand-AloneKeyboard InterfaceINSTALLATION FOR STAND-ALONE KEYBOARD INTERFACE1. Turn off the host system.2. Disconnect the keyboard from

Pagina 6 - SCANNER AND ACCESSORIES

10Figure 17: USB, InterfaceINSTALLATION FOR USB INTERFACE 1. Turn off the host system.2. Determine if your applicationrequires USB Keyboardcommunic

Pagina 7 - REPLACEMENT PARTS

11INSTALLATION FOR USB INTERFACEManufacturers Note:Plugging the scanner into the USB port of the PC does not guarantee thatscanned information will ap

Pagina 8 - BEFORE INSTALLING YOUR MS7600

12Figure 18: RS232 or Light PenInterfaceINSTALLATION FOR RS232 OR LIGHT PEN INTERFACES1. Turn off the host system.2. Connect the PowerLink cable int

Pagina 9 - Figure 7: Installation Tabs

13INSTALLATION FOR RS232 OR LIGHT PEN INTERFACESStep 7, page 12 continued.For RS232 Communication:Scan 1st ³999998Recall DefaultsScan 2nd ³415554Ena

Pagina 10 - Figure 10: Installation Tabs

14Figure 19: RS232/IBM, InterfaceINSTALLATION FOR IBM 46XX INTERFACE1. Turn off the host system.2. Connect the MVC cable to the1st jack down from th

Pagina 11 - MOUNTING THE MS7600 SERIES

15Figure 13: OCIA, InterfaceINSTALLATION FOR OCIA INTERFACE1. Turn off the host system.2. Connect the MVC cable to the2nd jack down from the top oft

Pagina 13 - Figure 15: Stand-Alone

16INSTALLATION OF A SECONDARY SCANNER1. Turn off the host system.2. Connect the round end of the PowerLink RS232 AUX cable [MLPN 54-54667A]to the RS2

Pagina 14 - Continued on next page

17INSTALLATION OF A SECONDARY SCANNER11. Scan the following bar code to configure the auxiliary port on the MS7600 toaccept a Metrologic scanner as t

Pagina 15 - Enable USB Defaults

18INSTALLATION OF A SECONDARY SCANNERFigure 20: Connector Orientation (Top)Secondary Scanner Setup (Bottom)

Pagina 16 - Interface

19SCANNER PARTSFigure 21: Scanner PartsnOutput Window (Laser Aperture)oAmber LED (Located Under Window)pRed LED (Located Under Window)qSpeakerrCable C

Pagina 17 - Step 7, page 12 continued

20MAINTENANCESmudges and dirt can interfere with the proper scanning of a bar code.Therefore, the output window will need occasional cleaning.For the

Pagina 18 - Load 46xx IBM Defaults

21SCANNER LABELSEach scanner has a label on the bottom of the unit. The label containsinformation such as the model number, date of manufacture, seria

Pagina 19 - Load OCIA Defaults

22AUDIBLE INDICATORSWhen the MS7600 scanner is in operation, it provides audible feedback. Thesesounds indicate the status of the scanner. Eight set

Pagina 20 - MLPN 54-54667A]

23VISUAL INDICATORSThere is a red LED and amber LED onthe front of the MS7600. When the scanner ison, the flashing or constant illumination of theLED

Pagina 21 - ³118412 ³318505

24FAILURE MODESFigure 25: LEDsFlashing Amber and One Razzberry ToneThis indicates the scanner has experienced alaser subsystem failure. Return the un

Pagina 22

25CHANGING THE BEEPER TONE & VOLUMEChanging the Beeper ToneBeeper tones may be programmed directly or incrementally using the followingbar code.

Pagina 23 - SCANNER PARTS

iiLOCATIONS CORPORATE HEADQUARTERS North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO90 Coles Road Tel: 856-228-8100Blackwoo

Pagina 24 - MLPN 49-00298

26POWER SAVE MODES AND IR DETECTIONThe MS7600 has five programmable power save modes. Refer to theMetroSelect Programming Guide for additional inform

Pagina 25 - SCANNER LABELS

27POWER SAVE MODES AND IR DETECTIONFigure 27: IR Activation Area Parallel to Package FlowSpecifications are subject to change without notice.

Pagina 26 - AUDIBLE INDICATORS

28SCAN VOLUME SPECIFICATIONS (BASED ON 100% UPC BAR CODES)Figure 28: Scan Volume in Plane Perpendicular to FlowFigure 29: Scan Volume in Plane Paralle

Pagina 27 - Figure 24: LEDs

29DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH(BASED ON 100% UPC BAR CODES)Figure 30: Depth of Field Perpendicular to FlowMinimum Bar Code Element

Pagina 28 - Figure 25: LEDs

30TROUBLESHOOTING GUIDEThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-METRO or 1-800-436-3876 to p

Pagina 29 - Changing the Beeper Volume

31TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONScanning a particularsymbology that is notenabled.UPC/EAN, Code 39, interleaved2

Pagina 30

32TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe bar code mayhave been printedincorrectly.Check if it is a checkdigit/charact

Pagina 31

33TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONEverythingworks exceptfor a couple ofcharacters.These characters maynot be suppo

Pagina 32 - SCAN VOLUME SPECIFICATIONS

34TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONCharacters arebeing dropped.Intercharacter delayneeds to be added tothe transmit

Pagina 33 - (BASED ON 100% UPC BAR CODES)

35DESIGN SPECIFICATIONSMS7600 SERIES DESIGN SPECIFICATIONSOPERATIONALLight Source: VLD 650 ± 10 nmLaser Power: 1.1 mW maximumDepth of Field:0 mm to 20

Pagina 34 - TROUBLESHOOTING GUIDE

iiiTABLE OF CONTENTSIntroduction... 1Scanner a

Pagina 35

36DESIGN SPECIFICATIONS (CONTINUED)MS7600 SERIES DESIGN SPECIFICATIONSELECTRICALInput Voltage: 5.2VDC ± 0.25VPower: 2.6 WOperating Current: 500 mALas

Pagina 36

37RS232 DEMONSTRATION PROGRAMIf an RS232 scanner is not communicating with your IBM compatible PC, keyin the following BASIC program to test that the

Pagina 37

38APPLICATIONS AND PROTOCOLSThe model number on each scanner includes the scanner number and factorydefault communications protocol.SCANNERVERSIONIDEN

Pagina 38 - MLPN 54-54667]

39DEFAULT SETTINGSMany functions of the scanner can be "programmed" - that is, enabled ordisabled. The scanner is shipped from the factory

Pagina 39 - DESIGN SPECIFICATIONS

40DEFAULT SETTINGS (CONTINUED)PARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XXKBW USBBars High as Scanned9Spaces High as Scanned9DTS/SIEMENS9DTS/NIXDORF*9

Pagina 40 - ENVIRONMENTAL

41DEFAULT SETTINGS (CONTINUED)PARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XXKBW USBNumber of Scan Buffers 199999 9Transmit EAN-8 Check Digit*99 99 9Tran

Pagina 41 - RS232 DEMONSTRATION PROGRAM

42DEFAULT SETTINGS (CONTINUED)PARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XXKBW USBUPC Suffix999Transmit AIM ID Characters999STX Prefix999ETX Suffix999C

Pagina 42 - COMMUNICATION PROTOCOL(S)

43DEFAULT SETTINGS (CONTINUED)PARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XXKBW USBCoupon Code 12899as code39999Programmable Code Lengths 7 avail.999999

Pagina 43 - DEFAULT SETTINGS

44DEFAULT SETTINGS (CONTINUED)Default settings for “Aux” interfaceThe secondary scanner and the MS7600 always communicate via RS232. Datais relayed t

Pagina 44 - DEFAULT SETTINGS (CONTINUED)

45SCANNER AND CABLE TERMINATIONSScanner Pinout ConnectionsThe MS7600 scanner interfaces terminate to 10-pin modular jacks located on theback of the un

Pagina 45

1INTRODUCTIONThe MS7600 Horizon™ series is Metrologic’s next generation in-counter laser barcode scanner. This compact, hands-free scanner is designe

Pagina 46

46SCANNER AND CABLE TERMINATIONS (CONTINUED)Figure 32: Scanner Interface PortsMS762x-37Keyboard Wedge,Stand-Keyboard or USBMS762x-37RS-232 or Light Pe

Pagina 47

47SCANNER AND CABLE TERMINATIONS (CONTINUED)Cable Connector Configurations (Host End)PowerLink Cable MLPN 54-54xxx*Pin Function1 Shield Ground2 RS-232

Pagina 48

48SCANNER AND CABLE TERMINATIONS (CONTINUED)Cable Connector ConfigurationThe PowerLink cable is terminated with a 5-pin DIN female connector onone end

Pagina 49 - Scanner Pinout Connections

49LIMITED WARRANTYThe MS7600 Series scanners are manufactured by Metrologic at its Blackwood, NewJersey, U.S.A. facility. The MS7600 Series scanners h

Pagina 50 - RS-232 or Light Pen

50NOTICESThis device complies with Part 15 of the FCC Rules. Operation is subject to thefollowing two conditions: (1) This device may not cause harmf

Pagina 51

51NOTICES (CONTINUED)AttentionL'emploi de commandes, réglages ou procédés autres que ceux décrits ici peutentraîner de graves irradiations. Le c

Pagina 52 - PowerLink Cable Adapter Cable

52PATENTS“Patent InformationThis METROLOGIC product may be covered by one or more of the followingU.S. Patents:U.S. Patent No.;4,960,985; 5,081,342;

Pagina 53 - LIMITED WARRANTY

53INDEX AAccessories ... 2Adapter ... 48Audible...

Pagina 54

54INDEXTTermination... 35Transformers ... 36Troubleshooting...30, 31, 32, 33, 34UUSB ...

Pagina 56

2SCANNER AND ACCESSORIESBASIC KITPart # DescriptionMS7600 Horizon™ Series Scanner00-02407B MetroSelect® Programming Guide00-02870B MS7600 Horizon Seri

Pagina 57 - INDEX

August 2002Printed in the USA 00-02870B

Pagina 58

3SCANNER AND ACCESSORIES (CONTINUED)OPTIONAL ACCESSORIESPart # DescriptionAC to DC Power Transformer - Regulated 5.2V@650 mA output45-45593 120V Unite

Pagina 59

4BEFORE INSTALLING YOUR MS7600When mounting the MS7600 or replacingthe Top Plate:DO NOT Presson the window.Figure 2Lift the Top plate straight up tore

Pagina 60 - 00-02870B

5MOUNTING THE MS7600 SERIESThere are three options for mounting your MS7600. Option “A” uses a shelf tosupport the unit. Option B lets the unit hang