Pagina 1 - METROLOGIC INSTRUMENTS, INC

METROLOGIC INSTRUMENTS, INC.MS700i Series Laser BarCode Projection ScannerInstallation and User’s GuideMLPN 2178 Printed in USAOctober 1998

Pagina 2 - Locations:

6Version 11 IBM 46XX ScannerOutput Format: IBM RS-485 serial input/output for the 4680 and 4690(46XX) point-of-sale terminalsThe Version 11 46XX inter

Pagina 3 - Table of Contents

7Configuring the ScannerLocated in the Version 11 scanner are two computer boards. One board is fordecoding and the other for 46XX IO processing. The

Pagina 4

8Configuring the IBM 46XXThe 4683 and 4693 terminals are configured on the store controller. The 4684and 4694 terminals are typically configured on th

Pagina 5 - Introduction

9Scanner Installation to a PC Keyboard PortThe MS700i/MS715i/MS720i/ scanner (version 17) provides keyboardemulation by converting the scanned bar cod

Pagina 6 - Unpacking List

10Figure 1To maintain compliance with applicable standards, all circuits connected to thescanner must meet the requirements for SELV (Safety Extra Low

Pagina 7

11PC Application Note: For most applications, it will be desirable to disable linefeed transmission. Fornon-USA keyboards, 10 mesc is probably the be

Pagina 8

12Figure 2Installation of the MS700 Series StandThe following are components used to build the MS700 Series stand(MLPN: 45483):1 Shoe Mount 4 Four Wo

Pagina 9 - Cloning Feature

13Figure 3Attaching the Scanner to the StandOnce the stand is securely mounted to the work surface, attach the scanner. The scanner has a “foot” that

Pagina 10 - Version 11 IBM 46XX Scanner

14Figure 4MS700i and MS720i Series Features1 Speaker The sound of a beep emits from here when thescanner performs a good read of a bar code.2 Green an

Pagina 11 - Configuring the Scanner

15Visual IndicatorsThere is a red LED and a green LED located on the scanner. When the scanner is on,the flashing or stationary activity of the LEDs a

Pagina 12 - Configuring the IBM 46XX

iiLocations:USA Corporate Headquarters EuropeMetrologic Instruments, Inc. Metrologic Instruments GmbH90 Coles Road Dornierstrasse 2Blackwood, NJ 0801

Pagina 13

16Signaux optiquesSur la partie supérieure du scanner se trouvent une diode LED rouge et une diode LEDverte. Quand le scanner est sous tension, les di

Pagina 14 - Figure 1

17Optische AnzeigenAuf dem Scanner befinden sich eine rote und eine grüne Leuchtdiode. Beieingeschaltetem Scanner geben Ihnen die blinkenden bzw. fest

Pagina 15

18Segnali otticiSullo scanner si trovano due diodi luminosi: uno rosso e uno verde. Quando lo scannerè inserito, i diodi luminosi, che possono o esser

Pagina 16 - Figure 2

19Volume SettingsThere are four volume settings available: low, medium, high and no volume.The operator can temporarily change the volume of the scan

Pagina 17 - Figure 3

20LabelsThere is one label located inside the window of each scanner noting that thedevice is a CDRH Class IIa laser product and IEC 825 LASERKLASSE 1

Pagina 18 - Figure 4

21InfraRed (IR) Object SensorAn infrared (IR) device located below the LEDs and above the scanner outputwindow (refer to the section, MS700i and MS720

Pagina 19 - Visual Indicators

22Symbol OrientationTo scan a symbol, it may be oriented in any of the degree angles shown inFigure 5. The roll, pitch, and yaw are 360E, ±60E, and ±6

Pagina 20 - Signaux optiques

23Active Scan Region for the MS700i and MS715i ScannerThe active scan region is the region within the depth of field of the five scansegments in which

Pagina 21 - Optische Anzeigen

24Active Scan Region for the MS720i ScannerThe active scan region is the region within the depth of field of the five scansegments in which the laser

Pagina 22 - Segnali ottici

25Horizontal Scan Width vs. Distance for the MS700iand MS715i ScannerThe following illustration notes the measurements of the horizontal scan widthat

Pagina 23 - Volume Settings

iiiTable of ContentsIntroduction ... 1Unpacking List ...

Pagina 24

26Horizontal Scan Width vs. Distance for the MS720iScannerThe following illustration notes the measurements of the horizontal scan widthat given dista

Pagina 25 - InfraRed (IR) Object Sensor

27Depth of Field for the MS700i and MS715i ScannerThrough the glass at the front of the scanner, safe, low powered laser beamsare projected in a compl

Pagina 26 - Symbol Orientation

28Depth of Field and Symbol Specification for theMS700i and MS715i (Refer to Figure 11)Code Type Minimum Small Code Density Depth of FieldElementMil.

Pagina 28 - Figure 7

30Depth of Field for the MS720i ScannerThrough the glass at the front of the scanner, safe, low powered laser beamsare projected in a complex pattern

Pagina 29 - Figure 8

31Depth of Field and Symbol Specification for theMS720i (Refer to Figure 13)Code Type Minimum Small Code Density Depth of FieldElementMil. (1/1000&quo

Pagina 31 - Figure 10

33MaintenanceSmudges and dirt can interfere with the proper scanning of a bar code.Therefore, the output window will need occasional cleaning.1. Spray

Pagina 32

34Appendix ASpecificationsApplication: Laser Bar Code Projection ScannerLight Source: VLD 675 ± 5 nm, Maximum output 1mWCDRH: CLASS IIa laser productE

Pagina 33 - Figure 11

35OperationalDepth of Field: MS700i, MS715i - 0.0mm - 178mm (0" - 7")MS720i - 178mm - 381mm (7" - 15")Scan Speed: MS700i, MS720

Pagina 34 - (Refer to Figure

ivActive Scan Region for the MS720i Scanner ... 25Horizontal Scan Width vs. Distance for the MS720i Scanner ... 26Depth o

Pagina 35 - MS720i (Refer to Figure 13)

36Appendix BDefault SettingsMany functions of the scanner can be "programmed" - that is, enabled ordisabled. The scanner is shipped from the

Pagina 36 - Figure 13

37Parameter Default OCIA IBM RS- Parallel Light Pen46XX 232*Minimum 04 T T T T TSymbol LengthSymbol Length None T T T T TLockSWEDA TFujitsu TOMRON * T

Pagina 37 - Applications and Protocols

38Parameter Default OCIA IBM RS- Parallel Light Pen46XX 232*Three Beeps on T T T T TTimeoutNo Beeps on T T T T TTimeoutIR Timeout 10 Min. T T T T TSam

Pagina 38 - Appendix A

39Parameter Default OCIA IBM RS- Parallel Light Pen46XX 232*Transmit UPC- * T T T TA NumberSystemTransmit T T T TCodabarStart/StopCharactersCLSI Editi

Pagina 39 - Roll, Pitch, Yaw:

40Parameter Default OCIA IBM RS- Parallel Light46XX 232* PenSTX Prefix TETX Suffix TCarriage Return * TLine Feed * TTab Prefix TTab Suffix T"DE

Pagina 40 - Appendix B

41Parameter Default OCIA IBM RS- Parallel Light Pen46XX 232*Special Software is required for the following:Two Digit T T T TSupplementsFive Digit T T

Pagina 41

42Appendix CPin AssignmentsVersions “1” and “21” Pin Assignments for RS-232, OCIA andLight Pen EmulationThe version “1” and “21” scanners head cables

Pagina 42

43Version “2” Pin Assignments for Parallel CommunicationThe version “2” scanner head cable is terminated with a male 25-pin D-typeconnector. To connec

Pagina 43

44Version “26” Pin Assignments for Multi-drop RS-422The version “26” scanner head cable is terminated with a male 25-pin D-typeconnector. To connect t

Pagina 44

45Versions “11” and “24” Pin Assignments for RS-485The version “11” and “24” scanners head cables are terminated with a male25-pin D-type connector. T

Pagina 45

1IntroductionThe MS700i Series Scanners are high throughput projection scanners that incorporate the latest in VLD (Visible Laser Diode) ASIC/VLSI and

Pagina 46 - Appendix C

46Version “17” Pin Assignments for Keyboard Wedge, RS-232 andLight Pen EmulationThe version “17” scanner head cable is terminated with a male 25-pin D

Pagina 47

47Appendix DWarranty and DisclaimerLimited WarrantyProducts manufactured by Metrologic have a 2-year limited warranty from date ofmanufacture.This war

Pagina 48

48DisclaimerMetrologic Instruments, Inc. and the author or authors make no claims or warranties with respectto the contents or accuracy of this public

Pagina 49

49Appendix ENoticesNoticeThis equipment has been tested and found to comply with limits for a Class A digital device,pursuant to Part 15 of the FCC Ru

Pagina 50

50AnmerkungNach Überprüfung dieses Geräts wurde festgestellt, daß es den Grenzwerten für Digitalgeräte derKlasse A gemäß Teil 15 der Richtlinien der U

Pagina 51 - Appendix D

51Appendix FPatents“Patent InformationThis METROLOGIC product may be covered by one or more of the followingU.S. Patents:U.S. Patent No. 4,360,798; 4,

Pagina 52

52Volume Control Card

Pagina 54

54IndexAAC input/outlet 3, 10, 34Adaptor 7, 10cable 6, 9kit 46Application 34Application and protocols 33Asia iiAssignmentspin 36-41Attaching stand 12

Pagina 55 - Appendix F

55Internet ii Power consumption 34Introduction 1 Power supply 2, 6, 34KKeyboard Wedge 9, 33, 35, 46LLabels 20LASERKLASSE 1 20LEDs 1, 3, 11, 14, 15-18,

Pagina 56 - Volume Control Card

2Unpacking ListThe shipping carton should contain the following:! Installation and User’s Guide (MLPN: 2178)! ScanSelect™ Scanner Programming Guide (

Pagina 57

56UUL/CSA/TUV 34USA corporate headquartersiiVVentilation 35Version identifiers 33Voltage 3, 10, 34Volume control card 52, 53WWarranty 47Watt(s) 1, 34W

Pagina 58

3Scanner Connections to the HostTo maintain compliance with applicable standards, all circuits connected to thescanner must meet the requirements for

Pagina 59

4Configuration of the Scanner to the Host SystemThe scanner is shipped from the factory programmed to a set of defaultconditions. These default condit

Pagina 60

5CLONINGCloning FeatureTo program several scanners with the same settings, use the Cloning feature.This is done by connecting the cloning cable (MLPN: