METROLOGIC INSTRUMENTS, INC. MS2220 StratosS™ Scanner / Diva Scale Installation and User’s Guide
4 INTRODUCTION REPLACEMENT PARTS REPLACEMENT PARTS Part # Description Caution Window types (Diamonex and Sapphire) are not interchangeable due
5INTRODUCTION GENERAL PRECAUTIONS The following are some general precautions to remember when handling your MS2200 Series scanner. DO NOT TU
6 INTRODUCTION MS2200 SERIES DESIGN SPECIFICATIONS Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: <1.5 mW M
7BASE MODEL CHARACTERISTICS MS2220 Scanner/Mettler Toledo DIVA Scale Components Figure 7. MS2220 Components
8 BASE MODEL CHARACTERISTICS MS2220 Scanner/Mettler Toledo DIVA Scale Components ITEM NO. DESCRIPTION OF ITEM IN FIGURE 7 1 Scale Zero Butto
9BASE MODEL CHARACTERISTICS MS2220 Scanner/Diva Scale Dimensions Figure 8. MS2220 Dimensions Specifications are subject to change without not
10 BASE MODEL CHARACTERISTICS MS2220 Scanner/Diva Scale Caution and Serial Number Labels Figure 10. MS2220 Label Locations (Top) and Examples
11 INSTALLATION QUICK INSTALLATION OUTLINE The following is a quick preview of the steps required for 1st time installations. Each item is disc
12 INSTALLATION SITE REQUIREMENTS Power Installation The Power Supply (AC/DC) should be connected to an AC Outlet that is free of electrical n
13INSTALLATION UNPACKING THE UNIT 1. Make sure the shipping box is top-side up before opening. 2. Remove the accessories box and check the
Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work ma
14 INSTALLATION UNPACKING THE UNIT MS2220 Package Warning There is a protective film located on the topside platter surface, vertical scan windo
15INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2220 Mounting Diagram Figure 17. MS2220 Mounting Diagram Specifications are subject to c
16 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 The following steps describe how to properly install the cables for an RS232 Stra
17INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 9. Turn on the host system. 10. Scan the recall Recall Defaults bar code. The
18 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB The following steps describe how to properly install the cables for a Full
19INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB 9. Turn on the host system. 10. Configure the StratosS to match the host
20 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB xx** Specifies international connection. See the Base Kit Component
21INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) IBM 46XX The following steps describe how to properly install the cables for an IBM 46xx
22 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) IBM 46XX 9. Turn on the host system. 10. Configure the StratosS to match the host syst
23INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) OCIA The following steps describe how to properly install the cables for an OCIA StratosS
iiTABLE OF CONTENTS INTRODUCTION Manual Scope ...
24 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) OCIA 8. Connect AC power to the transformer. If the AC outlet is equipped with an on/of
25INSTALLATION CABLE INSTALLATION (SECONDARY METROLOGIC SCANNER) The following steps describe how to properly install the cables between a seconda
26 INSTALLATION CABLE INSTALLATION (SECONDARY METROLOGIC SCANNER) † See Aux power notes on page 25 See power source caution statement on pa
27INSTALLATION EAS DEACTIVATION SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. The following is a
28 SCANNER OPERATION SCAN ZONE Figure 25. Checker-Side (13 mil) Figure 26. Horizontal Left/Right (13 mil) Specifications are subject
29SCANNER OPERATION SCAN ZONE Figure 27. Horizontal Direct (13 mil) Figure 28. Vertical Direct (13 mil) Specifications are subject to c
30 SCANNER OPERATION IR ACTIVATION AREA (IR LED OUTPUT) The StratosS’s default power save mode† is Dual Action Power Save Mode #2 (see page 36).
31SCANNER OPERATION INDICATOR DESCRIPTIONS Audible When in operation the StratosS provides audible feedback that indicates the status of the un
32 SCANNER OPERATION INDICATOR DESCRIPTIONS Visual (Continued) Steady Blue and Single White Flash When the scanner successfully reads a bar co
33SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display There is a two-digit error code display located under horizontal output
iiiTABLE OF CONTENTS SCANNER OPERATION Scan Zone...
34 SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display ERROR CODE DESCRIPTION 13 SCALE ERROR The scanner does not communicate
35SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display ERROR CODE DESCRIPTION 27 Laser #1 (Vertical) Undercurrent Warning – The
36 SCANNER OPERATION POWER SAVE MODES The MS2220 has five configurable power save modes. Refer to the MetroSelect Configuration Guide for additi
37SCANNER OPERATION BEEPER OPTIONS AND BUTTON FUNCTIONS Changing the Beeper Tone Beeper tones may be configured incrementally using the following
38 SCANNER OPERATION STARTUP When the scanner first receives power the white LED will flash, the blue LED will turn on and the scanner will beep
39SCALE OPERATION SCALE ZEROING After the unit has been officially calibrated (see page 40) the scale can be re-zeroed by pressing the scale zero
40 SCALE OPERATION CALIBRATION The scanner/Diva scale must be calibrated if: it is a first time installation the scale cannot be re-zeroed
41SCALE OPERATION CALIBRATION Priming the Scale for Calibration (lbs. or kg) Prime the scale before starting either method of calibration. Cal
42 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display* 1. Temporarily remove the platter and place it in
43SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display* 4. Reinstall the platter onto the scanner/Diva sca
ivTABLE OF CONTENTS SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections...
44 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display 7. Go to Group 2 Step 6 (Calibration) of the Service
45SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* The following calibration procedure can be used when the
46 ³996042SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* 4. Reinstall the platter onto the scanner/Diva sca
47³996044SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* Unit Calibration (Kilograms) For Pound weight units
48 SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* 6. Make sure there is no load on the scale platter. The
49SCALE OPERATION CALIBRATION VERIFICATION U.S. Pounds (lbs.) The following tests verify if the scale's Calibration is accurate. For Kilog
50 SCALE OPERATION CALIBRATION VERIFICATION Kilograms (kg) The following tests verify if the scale's Calibration is accurate. For US Pou
51SCALE OPERATION SECURITY SEAL INSTALLATION The certification of the weighing mechanism of the scale version of this scanner is subject to fede
52 SCALE OPERATION SECURITY SEAL INSTALLATION Wire Security Seal (Seal Conversion Kit MLPN 46-00359)* 1. Temporarily remove the platter and p
53MAINTENANCE HORIZONTAL SCAN WINDOW REPLACEMENT Figure 61. Platter/Horizontal Scan Window Replacement * See replacement parts on page 4.
54 MAINTENANCE VERTICAL SCAN WINDOW REPLACEMENT (MLPN 46-00232) Figure 62. Vertical Scan Window Replacement DAILY MAINTENANCE Smudges and d
55TROUBLESHOOTING The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to
56 TROUBLESHOOTING Symptom Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan (the white LED
57TROUBLESHOOTING Symptom Possible Cause(s) Solution RS232 Only The com port at the host is not working or is not configured properly. The cable
58 TROUBLESHOOTING RS232 DEMONSTRATION PROGRAM If an RS232 scanner is not communicating with your IBM compatible PC, key in the following BASIC
59DEFAULT SETTINGS COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is, enabled or disabled. The sca
60 DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB RSS Expanded Enable 9 9 9 9 Expanded ID “]e0” * 9
61DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Dual Action Power Save Mode #1 9 9 9 9 Dual Action
62 DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Transmit UK Plessey Check Digit 9 9 9 9 EAN 128 E
63DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Recv “i” = Transmit Scanner ID Byte 9 STX Prefix
1INTRODUCTION MANUAL SCOPE This guide provides information on the installation, setup and operation of Metrologic’s StratosS, MS2220 scanner/Div
64 DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA RS232 IBM 46XX USB Two Digit Redundancy 9 9 9 9 Five Digit Redundanc
65DEFAULT SETTINGS COMMUNICATION PARAMETERS Default settings for “Aux” interface The secondary scanner and the MS2220 series always communicates
66 SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS The MS2220 Series scanner interfaces terminate to 10-pin modular jacks located on t
67SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS Figure 64. Scale Connector Layout Scale RS232 to Host Scale Data, Dual Cable
68 SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS RS232 Interface Cable, MLPN 57-57210x-N-3 Pin Function ** 1 No Connect 2 RS23
69SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS Aux Port Configuration Cable*, MLPN 57-57008x-N-3 Pin Function** 1 No Connect
70 REGULATORY COMPLIANCE SAFETY ITE Equipment IEC 60950-1; EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN: 60825-1:1994+A1+A2 Ca
71REGULATORY COMPLIANCE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Class A Devices The following
72 REGULATORY COMPLIANCE EMC Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when
73LIMITED WARRANTY The MS2220 StratosS™ Series scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS2200
2 INTRODUCTION BASE KIT COMPONENTS BASE KIT COMPONENTS Part # Description MS2220-105Kz StratosS™ Scanner/Diva Scale D Diamonex Horizontal Wind
74 PATENTS For patent information, please refer to www.honeywellaidc.com/patents.
75INDEX A AC ... see power amber LED ...
76 INDEX R razzberry tone ...31, 32, 60 regulatory compliance ...
December 2006 (Version 1) Printed in the USA 00-02274A
3INTRODUCTION OPTIONAL ACCESSORIES AC to DC Power Transformer - Regulated Output: +5.2V @ 2A +12V @ 1A Part # Description 46-00226 120V U
Comentarios a estos manuales