DESIGN SPECIFICATIONS
MS3580
Operational
Normal Depth of Field: 19 mm - 273 mm (.75"- 10.75")
0.33 mm (13 mil)
bar code
Reduced Depth of Field: 19 mm - 146 mm (.75"- 5.75")
Omni Scan
Scan Speed: 1650 scan lines per second
No. of Scan Lines: 20
Single-Line
Scan Speed: 80 scan lines per second
No. of Scan Lines: 1
Motor Speed: 5000 RPM
Min Bar Width: 0.127 mm (5.0 mil)
Decode Capability: All standard 1-D bar codes including GS1 DataBar
System Interfaces:
RS232, Keyboard Wedge, Stand-Alone Keyboard, Light Pen
Emulation, RS485, USB (low speed and full speed), Laser
Emulation, RS232 TTL
Print Contrast: 35% minimum reflectance difference
No. Characters Read:
Up to 80 data characters
Maximum number will vary based on symbology and density.
Beeper Operation: 7 tones or no beep
Indicators (LED):
Blue = laser on, ready to scan
White = good read, decoding
Light Source Visible
Laser Diode:
650 nm
Maximum Laser Power: <1 mW (peak)
Embedded Laser
Max Optical Power: 10 mW
Wavelength: 640 – 660 nm
Specifications subject to change without notice.