Metrologic ARGUSSCAN MS7220 Guía de usuario

Busca en linea o descarga Guía de usuario para Lectores De Códigos De Barras Metrologic ARGUSSCAN MS7220. Metrologic ARGUSSCAN MS7220 User`s guide [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Installation and User’s Guide

METROLOGIC INSTRUMENTS, INC. MS7220 ArgusSCAN™ PresentationLaser ScannerInstallation and User’s Guide

Pagina 2 - LOCATIONS

7Figure 3: Keyboard Wedge InterfacesKeyboard WedgeINSTALLATION FOR KEYBOARD WEDGE INTERFACE1. Follow the “Getting Started” steps onpage 3.2. Turn of

Pagina 3 - TABLE OF CONTENTS

8Figure 4: Stand-Alone KeyboardInterfaceStand-AloneKeyboardINSTALLATION FOR STAND-ALONE KEYBOARD INTERFACE1. Follow the “Getting Started” steps onpag

Pagina 4 - INTRODUCTION

9Figure 5: RS232 or Light Pen InterfaceRS232orLight PenINSTALLATION FOR RS232 OR LIGHT PEN INTERFACES1. Follow the “Getting Started” steps onpage 3.

Pagina 5 - SCANNER AND ACCESSORIES

10INSTALLATION FOR RS232 OR LIGHT PEN INTERFACESStep 10, page 9 continued.For RS232 Communication:Scan 1st ³999998Recall DefaultsScan 2nd ³415554Ena

Pagina 6 - GETTING STARTED

11INSTALLATION OF AN AUXILIARY SCANNER1. Follow the “Getting Started” steps on page 3.2. Turn off the host system.3. Connect the Master/Slave Power

Pagina 7

12INSTALLATION OF AN AUXILIARY SCANNER OCIAKeyboardWedgeorStand-AloneKeyboardRS232orLightPenAuxConnectto Slave ScannerFigure 6: Master/Slave Setup

Pagina 8 - Figure 1: OCIA Interface

13SCANNER PARTS Output Window Red LED Green LED Speaker Side Cover Cable Door Cable Jack Cover Horizontal Mount Base Multi-Function Button(

Pagina 9 - For OCIA only)

14THE MULTI-FUNCTION BUTTONCHANGING THE BEEPER TONEA Short (<3 second) depression The beepertone will change. The new tone will beheard, followed

Pagina 10 - Keyboard Wedge

15AUDIBLE INDICATORSWhen the MS7220 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight set

Pagina 11 - Keyboard

16FAILURE MODESFlashing Green and One Razzberry ToneThis indicates the scanner has experienced a lasersubsystem failure. Return the unit for repair a

Pagina 12 - Light Pen

iiLOCATIONSCORPORATE HEADQUARTERS North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO90 Coles Road Tel: 856-228-8100Blackwood

Pagina 13 - Step 10, page 9 continued

17VISUAL INDICATORSThere is a red LED and a green LED on the front of the MS7220. When thescanner is on, the flashing or constant illumination of the

Pagina 14

18LABELSEach scanner has a label on the back of the unit. The label containsinformation such as the model number, date of manufacture, and the serialn

Pagina 15

19DEPTH OF FIELD SPECIFICATIONS (BASED ON 100% UPC BAR CODES)Depth of Field (default)Figure 10: Top View of Depth of FieldFigure 11: Side View of Dept

Pagina 16 - CANNER PARTS

20DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH(BASED ON 100% UPC BAR CODES)Depth of Field (Default)Figure 12: Top View of Depth of FieldSpecificat

Pagina 17 - THE MULTI-FUNCTION BUTTON

21DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH(BASED ON 100% UPC BAR CODES)Depth of Field (Default)Figure 13: Side View of Depth of FieldSpecifica

Pagina 18 - AUDIBLE INDICATORS

22TROUBLESHOOTING GUIDEThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-METRO or 1-800-436-3876 to p

Pagina 19 - FAILURE MODES

23TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe unit powersup, but doesnot scan and/orbeepScanning a particularsymbology tha

Pagina 20 - VISUAL INDICATORS

24TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONScanner beepsat some barcodes and NOTfor others of thesame bar codesymbologyThe

Pagina 21 - MAINTENANCE

25TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONAlphacharactersshow as lowercaseComputer is in CapsLock modeEnable Caps Lock det

Pagina 22 - DEPTH OF FIELD SPECIFICATIONS

26TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONPower-up OKand scans OKbut does notcommunicateproperly to thehost.Com port notop

Pagina 23 - Depth of Field (Default)

iiiTABLE OF CONTENTSIntroduction...1Scanner and Acces

Pagina 24

27RS232 DEMONSTRATION PROGRAMIf an RS232 scanner is not communicating with your IBM compatible PC,key in the following BASIC program to test that the

Pagina 25 - TROUBLESHOOTING GUIDE

28APPLICATIONS AND PROTOCOLSThe model number on each scanner includes the scanner number andfactory default communications protocol.ScannerVersionIden

Pagina 26

29DESIGN SPECIFICATIONSMS7220 DESIGN SPECIFICATIONSOPERATIONALLight Source: VLD 650 ± 10 nmLaser Power: 0.678 mW maximumDepth of Field: 0 mm to 215 mm

Pagina 27

30DESIGN SPECIFICATIONSMS7220 DESIGN SPECIFICATIONSELECTRICALInput Voltage: 5.2VDC ± 0.25VPower: 1.9 WOperating Current: 360 mADC Transformers: Class

Pagina 28

31DEFAULT SETTINGSMany functions of the scanner can be "programmed" - that is, enabled ordisabled. The scanner is shipped from the factory

Pagina 29 - MLPN 54-54667]

32DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBWDTS/NIXDORF*=NCR F=NCR S=Poll Light Pen Source=Beeper Tone Normal=====Bee

Pagina 30 - RS232 DEMONSTRATION PROGRAM

33DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBWConvert EAN-8 to EAN-13== ==Transmit UPC-A NumberSystem*=====Transmit UPC

Pagina 31 - APPLICATIONS AND PROTOCOLS

34DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBWCarriage Return*==Line Feed - disabled bydefault in KBW*==Tab Prefix==Tab

Pagina 32 - DESIGN SPECIFICATIONS

35DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBWCoupon Code 128==ascode39==Programmable CodeLengths7 avail.=====Programma

Pagina 33

36DEFAULT SETTINGS (CONTINUED)Default settings for “Aux” interfaceThe slave scanner and the MS7220 always communicate via RS232. Datais relayed to th

Pagina 34 - DEFAULT SETTINGS

1INTRODUCTIONArgusScan™ is an aggressive, omnidirectional laser barcode scanner idealfor retail, convenience, liquor, and specialty store applications

Pagina 35 - DEFAULT SETTINGS (CONTINUED)

37MS7220 STANDS Vertical Stand Kit [ MLPN 46-46405 ]See page 37 for installation instructions.Kit Includes:a. #8 x 1 round head wood screw [ MLPN 18-

Pagina 36

38MS7220 STANDSVertical Stand Installation [ MLPN 46-46405 ]Remove the three screwssecuring the cable cover to theunit and slide it up and off thescan

Pagina 37

39MS7220 STANDSOptional Flexible Stand Installation [ MLPN 46-46404 ]Remove the three screwssecuring the cable cover to theunit and slide it up and of

Pagina 38

40SCANNER AND CABLE TERMINATIONSScanner Pinout ConnectionsThe MS7220 scanner interfaces terminate to 10-pin modular jacks locatedon the back of the un

Pagina 39

41SCANNER AND CABLE TERMINATIONS (CONTINUED)MS7220Auxilary Port RS232 IN OnlyPin Function1 Ground2 RS-232 Receive Input3 RS-232 Transmit Output4RTS in

Pagina 40 - MS7220 STANDS

42SCANNER AND CABLE TERMINATIONS (CONTINUED)Cable Connector ConfigurationThe PowerLink cable is terminated with a 5-pin DIN female connectoron one end

Pagina 41

43LIMITED WARRANTYThe MS7220 scanners are manufactured by Metrologic at its Blackwood, New Jersey,U.S.A. facility. The MS7220 scanners have a two (2)

Pagina 42

44NOTICESNoticeThis equipment has been tested and found to comply with limits for a Class A digital device,pursuant to Part 15 of the FCC Rules. Thes

Pagina 43 - Scanner Pinout Connections

45NOTICES (CONTINUED)European StandardWarningThis is a class A product. In a domestic environment this product may cause radiointerference in which c

Pagina 44 - Powerlink Cable

46INDEX AAccessories ...2Adapter...2, 42Audible...15Autod

Pagina 45 - Cable Connector Configuration

2SCANNER AND ACCESSORIESThe following is a list of the parts included in the MS7220 kit.• MS7220 ArgusScan™ Presentation Scanner• MetroSelect® Progr

Pagina 46 - LIMITED WARRANTY

3GETTING STARTEDTools needed:• Phillips head screwdriver • ¼”-20 wrench• Drill with a #39 drill bit (drill for hard-mount installation only)Slide

Pagina 47

4GETTING STARTEDSee the “MS7220 Stands” section of this guide for additional information on the vertical[ MLPN 46-46405 ] and flexible [ MLPN 46-46406

Pagina 48 - NOTICES (CONTINUED)

5INSTALLATION FOR OCIA INTERFACETo power the unit with an external power supply:1. Follow the “Getting Started” steps onpage 3.2. Turn off the host

Pagina 49 - INDEX

6Figure 2: OCIA, Interface powered bythe host deviceOCIAINSTALLATION FOR OCIA INTERFACE (CONTINUED)To power the unit from the host device:(For OCIA o

Comentarios a estos manuales

Sin comentarios