MOUNTING SPECIFICATIONS
Enclosure Specifications
Minimum Allowable Window Position
Required To Avoid Detrimental Internal Reflective Beam Interference
at Positive Exit Beam Angle Tolerance
Figure 6.
Exit Beam
Elevation Angle α
Minimum Projected Distance
from the Engine’s Base to the
Window’s Internal Surface (L)
Minimum
Window Angle θ
+2.5° 5.0 28.0°
+2.5° 10.0 14.5°
+2.5° 15.0 10.5°
+2.5° 20.0 8.0°
+2.5° 25.0 7.0°
+2.5° 30.0 6.5°
+2.5° 35.0 6.0°
+2.5° 40.0 5.5°
+2.5° 45.0 5.0°
+2.5° 50.0 5.0°
Specifications are subject to change without notice.