Exposure Time for Image Acquisition
By default, the maximum exposure time for image acquisition is 8 ms. Reducing the exposure time for image
acquisition may improve the reading performance of high-density bar codes for certain applications. Use the
following bar codes to set the desired maximum exposure time.
Set Exposure Time to 1 ms
³ 3 2 7 6 1 0
Set Exposure Time to 2 ms
³ 3 2 7 6 1 2
Set Exposure Time to 3 ms
³ 3 2 7 6 3 0
Set Exposure Time to 4 ms
³ 3 2 7 6 4 0
Set Exposure Time to 5 ms
³ 3 2 7 6 5 0
Set Exposure Time to 6 ms
³ 3 2 7 6 6 0
Set Exposure Time to 7 ms
³ 3 2 7 6 7 0
Set Exposure Time to 8 ms
³ 3 2 7 6 0 0