METROLOGIC INSTRUMENTS, INC.IS6520/MS6520 Cubit® SeriesOmnidirectional Bar Code ScannerInstallation and User’s Guide

Pagina 2

4INSTALLATIONKeyboard Wedge (IS6520-47/MS6520-47)1. Turn off the host device.2. Plug the male 10-pin RJ45 end of thePowerLink cable into the 10-pin

Pagina 3 - LOCATIONS

5INSTALLATIONStand Alone Keyboard (IS6520-47/MS6520-47)1. Turn off the host device.2. Plug the male 10-pin RJ45 end of thePowerLink cable into the 1

Pagina 4 - TABLE OF CONTENTS

6DISCONNECTING THE POWERLINK CABLES FROM THE SCANNERBefore removing the cable from the scanner, Metrologic recommends that thepower on the host system

Pagina 5

7SCANNER PARTSA. SpeakerServes as an audible indicator.B. Green & Red LEDsDuring normal operation, the greenLED is on. This indicates that thel

Pagina 6

8STANDSFixed Vertical Stand (MLPN 46-46145)Optional purchase.a. Fixed Vertical Stand ... Qty. 1b. #7 x 1.00” Wood Screw ... Qty. 3c. M3 x 0.

Pagina 7 - INTRODUCTION

9AUDIBLE INDICATORSWhen the IS6520/MS6520 scanner is in operation, it provides audible feedback.These sounds indicate the status of the scanner. Eigh

Pagina 8 - SCANNER AND ACCESSORIES

10FAILURE MODESFlashing Green and One Razzberry ToneThis indicates the scanner has experienced a lasersubsystem failure. Return the unit for repair

Pagina 9

11VISUAL INDICATORSThere is a red LED and a green LED on IS6520/MS6520. When the scanner ison, the flashing or stationary, activity of the LEDs indic

Pagina 10 - INSTALLATION

12PROGRAMMING MODESThe IS6520/MS6520 Cubit has 3 modes of programming.Bar Codes: Cubit can be configured by scanning the bar codes located in theMetr

Pagina 11

13PROGRAMMING MODES (CONTINUED)6. To enter serial program mode, send the following command [stx]999999[etx].7. To exit serial program mode, send the

Pagina 13 - MOUNTING HOLES

14PROGRAMMING MODES (CONTINUED)EXAMPLE #3: The following example shows the events that occur when aninvalid bar code is sent. This sample will load t

Pagina 14

15LABELSEach scanner has a label on the back of the unit that lists the model number,date of manufacture, serial number, CE and caution information.

Pagina 15 - AUDIBLE INDICATORS

16OPTIMAL LOW AND CLOSE DEPTH OF FIELDMinimum Bar Code Element WidthABCDE FGHJ Kmm- .15 - .17 - - .25 .33 .53 -mils- 5.7 - 6.8 - - 10 13 21 -Note: Th

Pagina 16 - FAILURE MODES

17OPTIMAL HIGH AND NORMAL DEPTH OF FIELDMinimum Bar Code Element WidthABCDE FGHJ Kmm- .15 - .17 - - .25 .33 .53 -mils- 5.7 - 6.8 - - 10 13 21 -Note:

Pagina 17 - VISUAL INDICATORS

18FAR DEPTH OF FIELDMinimum Bar Code Element WidthABCDE FGHJ Kmm- .15 - .17 - - .25 .33 .53 -mils- 5.7 - 6.8 - - 10 13 21 -025507510012515017520025022

Pagina 18 - PROGRAMMING MODES

19TROUBLESHOOTING GUIDEThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-METRO or 1-800-436-3876 to

Pagina 19 - PROGRAMMING MODES (CONTINUED)

20TROUBLESHOOTING GUIDE (CONTINUED)All InterfacesIS6520/MS6520 Series Troubleshooting Guide (continued)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe unitpowe

Pagina 20

21TROUBLESHOOTING GUIDE (CONTINUED)All InterfacesIS6520/MS6520 Series Troubleshooting Guide (continued)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONScanner beep

Pagina 21 - MAINTENANCE

22TROUBLESHOOTING GUIDE (CONTINUED)RS232 onlyIS6520/MS6520 Series Troubleshooting Guide (continued)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONPowers up OKand

Pagina 22

23APPENDIX ADesign SpecificationsOperationalLight Source: VLD 650 ± 10 nm, 0.681 milliwatts (PEAK)Depth of Field: 0 mm to 176 mm (0” to 7”) for 0.33 m

Pagina 23

iiLOCATIONSCorporate Headquarters North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO90 Coles Road Tel: 856-228-8100Blackwood

Pagina 24 - FAR DEPTH OF FIELD

24APPENDIX A (CONTINUED)Design SpecificationsElectricalPower: 1.0 WInput Voltage: 5 VDC ± 0.25 VOperating Current: 200 mA typical @5VDCDC Transformers

Pagina 25 - TROUBLESHOOTING GUIDE

25APPENDIX BDefault SettingsMany functions of the scanner can be "programmed" - that is, enabled ordisabled. The scanner is shipped from th

Pagina 26

26APPENDIX B (CONTINUED)Parameter Default RS232*LightPenKBWDTS/NIXDORF*NCR FNCR SPoll Light Pen Source9Beeper Tone Normal9 9 9Beep/Transmit SequenceBe

Pagina 27

27APPENDIX B (CONTINUED)Parameter Default RS232*LightPenKBWTransmit UPC-A Manufacturer ID#*9 9 9Transmit UPC-A Item ID#*9 9 9Transmit Codabar Start/St

Pagina 28

28APPENDIX B (CONTINUED)Parameter Default RS232*LightPenKBWMessage RTS/CTS9XON/XOFF Handshaking9ACK/NA K9Two Digit Supplements9as code 399Five Digit S

Pagina 29 - APPENDIX A

29110APPENDIX CScanner Pinout ConnectionsThe IS6520/MS6520 scanner interfaces terminateto a 10-pin modular jack. The serial # labelindicates the inter

Pagina 30 - APPENDIX A (CONTINUED)

30APPENDIX C (CONTINUED)Keyboard Wedge Powerlink and Adapter Cable (MLPN 54-54008)The Keyboard Wedge PowerLink cable is terminated with a 5-pin DIN fe

Pagina 31 - Default Settings

31APPENDIX DWarranty and DisclaimerLimited WarrantyThe IS6520/MS6520 Cubit® scanners are manufactured by Metrologic at itsBlackwood, New Jersey, U.S.A

Pagina 32 - PPENDIX B (CONTINUED)

32APPENDIX ENoticesNoticeThis equipment has been tested and found to comply with limits for a Class A digital device, pursuant toPart 15 of the FCC Ru

Pagina 33

33APPENDIX E (CONTINUED)European StandardWarningThis is a class A product. In a domestic environment this product may causeradio interference in whic

Pagina 34 - APPENDIX B (CONTINUED)

iiiTABLE OF CONTENTSIntroduction...1Scanner and Accessori

Pagina 35 - APPENDIX C

35APPENDIX F Patents For patent information, please refer to www.honeywellaidc.com/patents.

Pagina 36 - APPENDIX C (CONTINUED)

35INDEXAAC input/outlet...2, 3, 4, 5, 29Accessories...2Approvals ...15, 32, 33Assignmen

Pagina 37 - APPENDIX D

36INDEXOOperating current ...24Operating temperture ...24Operation...9, 23, 32Operational.

Pagina 39 - APPENDIX E (CONTINUED)

July 2004Printed in the USA 00 - 02421B

Pagina 40 - APPENDIX F

ivTABLE OF CONTENTSAppendix CScanner Pinout Connections ...29Cable Connector Configuration

Pagina 42

1INTRODUCTIONMetrologic's Cubit® Series of compact omnidirectional bar code scannersincludes the MS6520 for retail applications and the IS6520 fo

Pagina 43

2SCANNER AND ACCESSORIESBASIC KIT COMPONENTSPart No. DescriptionIS6520/MS6520 Cubit® Omnidirectional Scanning Engine00-02421 Installation and User’s G

Pagina 44 - 00 - 02421B

3INSTALLATIONRS232, Light Pen (IS6520-41/MS6520-41)1. Turn off the host device.2. Plug the male 10-pin RJ45 end of thePowerLink cable into the 10-pi

Comentarios a estos manuales

Sin comentarios