Bar Code Calibration Procedure without Remote Display*
4. Reinstall the platter onto the scanner/Diva scale (see Figure 48).
Figure 48. Platter Installation
5. Enter bar code calibration mode. Use the vertical window to scan one of the following bar codes, whichever weight
units (either pounds or kilograms) the scanner/Diva scale will be operating in. The scanner will beep once as it enters the
bar code calibration mode and the calibration utility will start.
Unit Calibration (Pounds)
For Kilogram weight units see instructions on page 47.
Figure 49. Entering Bar Code Calibration Mode (Pounds)
If a razz tone sounds, an error has occurred. Refer to Diagnostic Indicator Display; Error Codes starting on
page 33 for additional information.
* These procedures are for MS2220 StratosS Scanner/Diva Scale models only.