IS3480 QuantumEScan Engine User’s Guide
6 INSTALLATION RS232, RS232 TTL, Light Pen or Laser Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink
7 INSTALLATION RS485 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the IS3480. 3.
8 INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on th
9 INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socke
10 INSTALLATION Low Speed USB (Integrated) 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB PowerLink cable into the 10-
11 INSTALLATION Notes for Laser Emulation IS3480-104 Only The IS3480-104 leaves the factory with the Laser Emulation Mode enabled. If the Reca
12 SCANNER OPERATION Configurable Primary and Secondary Scan Pattern Modes There are two configurable scan pattern modes available with the IS34
13 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED For illustration purposes the un
14 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED For illustration purposes the
15 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE ENABLED For illustration purposes the un
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document
16 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE DISABLED For illustration purposes the u
17 SCANNER OPERATION Sweet Spot Mode The sweet spot mode is used to determine where the maximum read rate area or “sweet spot” is located for a
18 SCANNER OPERATION Audible Indicators When the IS3480 is in operation, it can provide audible feedback. These sounds indicate the status of the
19 SCANNER OPERATION Visual Indicators There are four LEDs located on the top of the IS3480. When the scanner is on, the flashing or constant il
20 SCANNER OPERATION Failure Mode Indicators Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsy
21 SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 9. Norma
22 SCANNER OPERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 10. Redu
23 SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15
24 SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .1
25 SCANNER OPERATION IR Activation Range* QuantumE’s default power save mode† is Laser OFF. This power save mode turns the laser off after a co
ii TABLE OF CONTENTS Introduction Product Overview ... 1
26 TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Honeywell representative to preserve the limited warranty
27 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan (the whi
28 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution RS232 Only The unit powers up OK and scans OK but does not communicate properly to t
29 DESIGN SPECIFICATIONS IS3480 Operational Normal Depth of Field: 25 mm - 280 mm (1"- 11") 0.33 mm (13 mil) bar code Reduced Dept
30 DESIGN SPECIFICATIONS IS3480 Mechanical Width: 63 mm (2.48") Depth: 50 mm (1.97") Height: 68 mm (2.68") Weight: 6 oz (170 g
31 APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER V
32 CONFIGURATION MODES The IS3480 Series scanner has three modes of configuration. • Bar Codes The IS3480 can be configured by scanning the bar c
33 UPGRADING THE FIRMWARE The IS3480 is part of Honeywell's line of scanners with flash upgradeable firmware. The upgrade process requires, a
34 DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The sca
35 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USB RS232* OR RS232 TTL LIGHT PEN RS485 KBW LASER EMULATION Expanded ID “]e0” *
iii TABLE OF CONTENTS IR Activation Range ... 25 Troubleshooti
36 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USB RS232* OR RS232 TTL LIGHT PEN RS485 KBW LASER EMULATION Transmit UPC-A Che
37 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USB RS232* OR RS232 TTL LIGHT PEN RS485 KBW LASER EMULATION Nixdorf ID
38 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USB RS232* OR RS232 TTL LIGHT PEN RS485KBW LASER EMULATION Supplements are not
39 SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The IS3480 scanner interfaces terminate to a 10-pin modular socket. The serial numbe
40 SCANNER AND CABLE TERMINATIONS Figure 15. IS3480-104 RS232, RS232 TTL, or Laser Emulation Pin Function 1 Ground 2 RS232 Transmit Output 3 RS2
41 SCANNER AND CABLE TERMINATIONS Figure 16. Figure 17. Zero Insertion Force Connector (ZIF), 6-pin Utility Connector Pin Function 1 Aux +5V:
42 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable 53-53000x-3 coiled or 59-59000x-3 straight
43 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 59-59002x-3 Pin Function 5-Pin DIN,
44 REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1: Second Edition EN 60950-1: Second Edition Laser Laser Class 1: IEC 60825-1: Second Ed
45 REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 NOTE: Immunity performance is not
1 INTRODUCTION QuantumE is a miniature, omni-directional scanning engine with optional single-line scanning capability. The self-contained device
46 REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s autho
47 LIMITED WARRANTY Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in mater
48 LIMITED WARRANTY All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unen
49 INDEX A AC ... 2, 6–10 Accessories ... 2, 3 Adapter ...
50 INDEX M Maintenance ... 3 Manual... 2, 18, 31 MetroSelect ...
51 CUSTOMER SUPPORT Technical Assistance If you need assistance installing or troubleshooting your device, please contact us by using one of the
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-02026 Rev K 6/12
2 INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description IS3480 QuantumE Scanner 00-02026 IS3480 User’s Guide * 00-02407
3 INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description 59-59002x-3 Keyboard Wedge PowerLink cable 59-59020x-3 Stand
4 INTRODUCTION Scanner Components Figure 1a. Scanner Components ITEM NO. DESCRIPTION 1 Utility Connector Located Under Rubber Seal The rubber
5 INTRODUCTION Caution and Serial Number Labels Figure 2. Caution To maintain compliance with applicable standards, all circuits connected
Comentarios a estos manuales