Metrologic IS3480 QuantumE Guía de usuario Pagina 34

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 56
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 33
DESIGN SPECIFICATIONS
IS3480
Mechanical
Width: 63 mm (2.48")
Depth: 50 mm (1.97")
Height: 68 mm (2.68")
Weight: 6 oz (170 g)
Electrical
Voltage Supply: 5VDC ± 0.25V
Operating Power: 1.375 W
Standby Power: 1.0 W
Operating Current: 275 mA typical at 5VDC
Standby Current: 200 mA typical at 5VDC
DC Transformers: Class II; 5.2VDC @ 1A
For regulatory compliance information, see pages 4446.
Environmental
Operating Temperature: -20°C to 40°C (-4°F to 104°F)
Storage Temperature: -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% relative humidity, non-condensing
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None required
Specifications subject to change without notice.
Vista de pagina 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 55 56

Comentarios a estos manuales

Sin comentarios