Metrologic Hand-Held Scanner Guía de usuario Pagina 40

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 52
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 39
36
Parameter Default OCIA IBM RS-232 Light Keyboard
46XX Pen Wedge
Emulating IBM 4500 T
Emulating 3687/4014 T
Emulating IBM 1520 * T
No Inter Record Delay T
25 Millisecond (msc) * T
Inter Record Delay
50 msc Inter Record Delay T
125 msc Inter Record Delay T
Bars High * T
Spaces High T
Transmit as Scanned * T
Transmit as Code 39 T
Poll Light Pen 5 Volts T
No Poll Light Pen * T
UPC * T T T T T
EAN * T T T T T
Code 39 * T T T T T
Codabar * T T T T T
Code 128 * T T T T T
Code 93 * T T T T T
Interleaved 2 of 5 (ITF) * T T T T T
MSI - Plessey Decode T T T T T
Enable Code 11 Decode T T T T T
Enable Airline 2 of 5 T T T T T
Full ASCII Code 39 T T T T T
Italian Pharmaceutical T T T T T
Minimum 1 Character T T T T T
Code Length
Minimum 3 Character * T T T T T
Code Length
Minimum 6 Character T T T T T
Code Length
Transmit UPC-A Number Sys * T T T T T
UPC-A Check Digit Transmit * T T T T T
Convert UPC-A to EAN-13 T T T T
Expand UPC-E T T T T
UPC-E Check Digit Transmit T T T T
UPC-E Leading 0 Transmit T T T T
EAN-8 Check Digit Transmit * T T T T T
EAN-13 Check Digit Transmit * T T T T T
2 Digit Supps (Scan) T T T
Vista de pagina 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 51 52

Comentarios a estos manuales