DESIGN SPECIFICATIONS
MS7120
Electrical
Voltage Supply: 5VDC ± 0.25V
Operating Power: 0.9 W
Standby Power: 0.85 W
Operating Current: 180 mA typical at 5VDC
Standby Current: 170 mA typical at 5VDC
DC Transformers: Class II; 5.2VDC @ 1A
For regulatory compliance information, see pages 30 - 32.
Environmental
Operating Temperature: -20°C to 40°C (-4°F to 104°F)
Storage Temperature: -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% relative humidity, non-condensing
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None required
Specifications subject to change without notice.