Pagina 1 - Bar Code Scanner

METROLOGIC INSTRUMENTS, INC. MS2421 / MS2422 Bar Code Scanner Installation and User’s Guide

Pagina 2

6 BASE MODEL CHARACTERISTICS MS2421 Scanner Components Figure 5. MS2421 Components Components ITEM NO. DESCRIPTION OF ITEM 1 Volume/Tone

Pagina 3 - ABLE OF CONTENTS

7BASE MODEL CHARACTERISTICS MS2421 Scanner Dimensions Figure 6. MS2421 Dimensions Connector Panel Figure 7. MS2421 Connector Panel *

Pagina 4

8 BASE MODEL CHARACTERISTICS MS2421 Scanner Caution and Serial Number Labels Figure 8. MS2421 Label Locations (Top) and Examples (Bottom)

Pagina 5 - INTRODUCTION

9BASE MODEL CHARACTERISTICS MS2422 Scanner Components Figure 9. MS2422 Components Components ITEM NO. DESCRIPTION OF ITEM IN FIGURE 15 1

Pagina 6

10 BASE MODEL CHARACTERISTICS MS2422 Scanner Dimensions Figure 10. MS2422 Dimensions Connector Panel Figure 11. MS2422 Connectors

Pagina 7

11BASE MODEL CHARACTERISTICS MS2422 Scanner Caution and Serial Number Labels Figure 12. MS2422 Label Locations (Top) and Examples (Bottom)

Pagina 8

12 INSTALLATION QUICK INSTALLATION OUTLINE The following is a quick preview of the steps required for 1st time installations. Each item is disc

Pagina 9

13INSTALLATION UNPACKING THE UNIT 1. Make sure the shipping box is top-side up before opening. 2. Remove the accessories box and check the

Pagina 10 - BASE MODEL CHARACTERISTICS

14 INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2421 Mounting Diagram Figure 17. MS2421 Mounting Diagram Specifications are subject to

Pagina 11

15INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2422 Mounting Diagram Figure 18. MS2422 Mounting Diagram Specifications are subject to

Pagina 12

Copyright © 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may b

Pagina 13

16 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 The following steps describe how to properly install the cables for an RS232 appli

Pagina 14

17INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 xx** Specifies international connection. See the Base Kit Components and Opti

Pagina 15

18 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB The following steps describe how to properly install the cables for a Full

Pagina 16 - INSTALLATION

19INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB Step 8 is for USB Serial Emulation Mode or Keyboard Emulation Mode only.

Pagina 17

20 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) IBM 46XX The following steps describe how to properly install the cables for an IBM 46xx

Pagina 18

21INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) IBM 46XX xx** Specifies international connection. See the Base Kit Components and O

Pagina 19

22 INSTALLATION CABLE INSTALLATION (SECONDARY METROLOGIC SCANNER) The following steps describe how to properly install the cables between a second

Pagina 20 - NSTALLATION

23INSTALLATION CABLE INSTALLATION (SECONDARY METROLOGIC SCANNER) † See Aux power notes on page 22 See power source caution statement on pag

Pagina 21

24 INSTALLATION EAS DEACTIVATION SW1 and SW2 are the switch banks inside the Checkpoint device that set the deactivation range. The following is

Pagina 22

25SCANNER OPERATION SCAN ZONE Figure 25. Checker-Side (13 mil) Figure 26. Horizontal Left/Right (13 mil) Specifications are subject to c

Pagina 23

iiTABLE OF CONTENTS INTRODUCTION Manual Scope ...

Pagina 24

26 SCANNER OPERATION SCAN ZONE Figure 27. Horizontal Direct (13 mil) Figure 28. Vertical Direct (13 mil) Specifications are subject to

Pagina 25

27SCANNER OPERATION WAKE ACTIVATION AREA (PHOTOCELL LED OUTPUT) The MS2421/MS2422 scanner’s default power save mode† is Dual Action Power Save Mod

Pagina 26

28 SCANNER OPERATION WAKE ACTIVATION AREA SENSITIVITY (PHOTOCELL LED OUTPUT RANGE) Changing the Wake Area Sensitivity Level (Photocell LED Range A

Pagina 27

29Figure 30. Blue LED SCANNER OPERATION INDICATOR DESCRIPTIONS Audible When in operation, the MS2421/MS2422 scanner provides audible feedback

Pagina 28

30 SCANNER OPERATION INDICATOR DESCRIPTIONS Visual Steady Blue When all lasers are active, the blue LED is illuminated. The blue LED will rema

Pagina 29 - SCANNER OPERATION

31SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display There is a two-digit error code display located under horizontal output

Pagina 30

32 SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display ERROR CODE DESCRIPTION 11 SWITCH ERROR – The switch used for volume se

Pagina 31

33SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display ERROR CODE DESCRIPTION 29 LASER #3 (LEFT HORIZONTAL) UNDERCURRENT WARNIN

Pagina 32

34 SCANNER OPERATION POWER SAVE MODES The MS2421/MS2422 bar code scanners have five configurable power save modes. Refer to the MetroSelect Conf

Pagina 33

35SCANNER OPERATION BEEPER OPTIONS AND BUTTON FUNCTIONS Changing the Beeper Tone Beeper tones may be configured incrementally using the following

Pagina 34

iiiTABLE OF CONTENTS SCANNER OPERATION Scan Zone...

Pagina 35

36 SCANNER OPERATION STARTUP When the scanner first receives power, the blue LED will turn on and the scanner will beep once. The scanner is now

Pagina 36

37MAINTENANCE HORIZONTAL SCAN WINDOW REPLACEMENT After the replacement platter has been installed, remove all protective film from the new p

Pagina 37

38 MAINTENANCE DAILY MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the horizontal and vertical

Pagina 38

39TROUBLESHOOTING The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to

Pagina 39

40 TROUBLESHOOTING Symptom Possible Cause(s) Solution All Interfaces The print quality of the bar code is suspect. Check the character length lo

Pagina 40

41TROUBLESHOOTING Symptom Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanner and h

Pagina 41 - MAINTENANCE

42 DEFAULT SETTINGS COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is, enabled or disabled. The sc

Pagina 42

43DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 IBM 46XX USB RSS Expanded Enable 9 9 9 Expanded ID “]e0” * 9 9 9 RSS

Pagina 43 - TROUBLESHOOTING

44 DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 IBM 46XX USB Dual Action Power Save Mode #2 * 9 9 9 Same Symbol Rescan

Pagina 44

45DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 IBM 46XX USB EAN 128 Enable 9 9 9 Enable French Pharma 9 9 9 Enable

Pagina 45

1INTRODUCTION MANUAL SCOPE This guide provides information on the installation, setup and operation of the MS2421 and the MS2422 scanner only mo

Pagina 46 - DEFAULT SETTINGS

46 DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 IBM 46XX USB STX Prefix 9 9 TAB Prefix 9 9 Metrologic Prefix 9 9 U

Pagina 47

47DEFAULT SETTINGS COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 IBM 46XX USB Five Digit Redundancy 9 9 9 Enable Coupon Code 128 9 9

Pagina 48

48 DEFAULT SETTINGS COMMUNICATION PARAMETERS Default settings for “Aux” interface The secondary scanner and the MS2421/MS2422 scanner always com

Pagina 49

49SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS The MS2421/MS2422 scanner terminates to 10-pin modular jacks located on the bottom o

Pagina 50

50 SCANNER AND CABLE TERMINATIONS SCALE READY MS2421 MODELS – ADDITIONAL PINOUT CONNECTIONS There are four additional 10-pin modular jacks locate

Pagina 51

51SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS The following cables are examples of some of the standard cables that may be shi

Pagina 52

52 SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS Aux Port Configuration Cable*, MLPN 57-57008x-N-3 Pin Function** 1 No Connect

Pagina 53 - SCANNER PINOUT CONNECTIONS

53REGULATORY COMPLIANCE SAFETY ITE Equipment IEC 60950-1; EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN: 60825-1:1994+A1+A2 Cau

Pagina 54 - Display

54 REGULATORY COMPLIANCE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Class A Devices The following

Pagina 55 - MLPN 57-57212x-N-3

55REGULATORY COMPLIANCE EMC Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when

Pagina 56 - *, MLPN 57-57008x-N-3

2 INTRODUCTION BASE KIT COMPONENTS BASE KIT COMPONENTS Part # Description MS242x-105Nz Bar Code Scanner 1 Scanner Only, Scale Ready – Compact

Pagina 57 - REGULATORY COMPLIANCE

56 LIMITED WARRANTY The MS2400 Series bar code scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility and at its Su

Pagina 58

57PATENTS Patent Information This METROLOGIC product may be covered by, but not limited to, one or more of the following U.S. Patents: U.S. Pate

Pagina 59

58 INDEX A AC ... see power application ...

Pagina 60 - LIMITED WARRANTY

59INDEX S safety...54, 55 Scale ...

Pagina 63

July 2007 (Version 02) Printed in the USA 00-05311A

Pagina 64

3INTRODUCTION OPTIONAL ACCESSORIES OPTIONAL ACCESSORIES Part # Description AC to DC Power Transformer - Regulated Output: +5.2V @ 2.5A +12V @

Pagina 65

4 INTRODUCTION GENERAL PRECAUTIONS The following are some general precautions to remember when handling the MS2421/MS2422 scanner. DO NOT T

Pagina 66 - 00-05311A

5INTRODUCTION MS2421 / MS2422 SCANNER DESIGN SPECIFICATIONS Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: &l