Metrologic MS7620-13 Guía de usuario

Busca en linea o descarga Guía de usuario para Lectores De Códigos De Barras Metrologic MS7620-13. Metrologic MS7620-13 User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Horizon7600
Presentation Laser Imager
Installation and User’s Guide
Vista de pagina 0
1 2 3 4 5 6 ... 63 64

Indice de contenidos

Pagina 1 - Horizon™ 7600

Horizon™ 7600 Presentation Laser Imager Installation and User’s Guide

Pagina 2 - Patents

6 Scanner Labels Each scanner has a label on the bottom of the unit. The label contains information such as the model number, date of manufacture, se

Pagina 3 - Table of Contents

7 MS7625 Series Only (except RS485 Interface) If the following label is attached to your product, the product meets Korean agency approval for Class

Pagina 4

8 Mounting Before Installing Your 7600 When mounting the 7600 or replacing the Top Plate: DO NOT Press on the window. Fi

Pagina 5 - Introduction

9 Mounting the 7600 Series There are three options for mounting your 7600. Option A uses a shelf to support the unit. Option B lets the unit hang

Pagina 6 - Optional Accessories

10 Option B: Free Hanging Support Figure 10: Package Flow (right) Figure 11: Specifications for Free Hanging Support Figure 12: Installation

Pagina 7 - Replacement Parts

11 Option C: Trim Ring Figure 13: Counter Top Opening for Trim Ring (PN 46-46641) Figure 14: Trim Ring (PN 46-46641) Installation

Pagina 8 - Scanner Parts

12 Figure 15: Keyboard Wedge Interfaces Installation Keyboard Wedge 1. Turn off the host system. 2. Disconnect the keyboard from the host. 3

Pagina 9 - Maintenance

13 Figure 16: Stand-Alone Keyboard Interface Stand-Alone Keyboard 1. Turn off the host system. 2. Disconnect the keyboard from the host. 3. Co

Pagina 10 - Scanner Labels

14 Figure 18: USB, Interface USB 1. Turn off the host system. 2. Determine if your application requires USB Keyboard communication protocols or

Pagina 11

15 Manufacturers Note: Plugging the scanner into the USB port of the PC does not guarantee that scanned information will appear at the PC. A softwar

Pagina 12 - Mounting

Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this documen

Pagina 13 - Mounting the 7600 Series

16 Figure 19: RS232 or Light Pen Interface RS232 or Light Pen 1. Turn off the host system. 2. Connect the PowerLink cable into the 1st jack do

Pagina 14 - Figure 12: Installation Tabs

17 For RS232 Communication: Scan 1st³ 9 9 9 9 9 8 Scan 2nd³ 4 1 5 5 5 4 For Light Pen Communication: Scan 1st³ 9 9

Pagina 15 - Option C: Trim Ring

18 Figure 20: RS232/RS485, Interface RS485 1. Turn off the host system. 2. Connect the MVC cable to the 1st jack down from the top of the 7600

Pagina 16 - Installation

19 Figure 21: OCIA, Interface OCIA 1. Turn off the host system. 2. Connect the MVC cable to the 2nd jack down from the top of the 7600. 3.

Pagina 17 - Stand-Alone Keyboard

20 Secondary Scanner 1. Turn off the host system. 2. Connect the round end of the PowerLink RS232 AUX cable [PN 54-54667A] to the RS232 jack of

Pagina 18 - PN 46-46640) into the slot

21 11. Scan the following bar code to configure the auxiliary port on the 7600 to accept a Honeywell scanner as the secondary scanner. The follo

Pagina 19 - ³ 9 9 9 9 7 8

22 Figure 22: Connector Orientation Figure 23: Secondary Scanner Setup

Pagina 20 - RS232 or Light Pen

23 EAS EAS Deactivation Antenna SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. Honeywell recommend

Pagina 21 - ³ 4 1 5 5 2 4

24 Operation Audible Indicators When the 7600 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanne

Pagina 22 - ³ 9 9 9 9 9 5

25 Visual Indicators There is a red LED and amber LED on the front of the 7600. When the scanner is on, the flashing or constant illumination of

Pagina 23 - ³ 9 9 9 9 9 3

i Table of Contents Introduction ... 1 Base Kit

Pagina 24 - Secondary Scanner

26 Failure Modes Figure 26: LEDs Flashing Amber and One Razzberry Tone This indicates the scanner has experienced a laser subsystem failure. Re

Pagina 25 - ³ 4 3 7 3 3 0

27 Changing the Beeper Tone & Volume Changing the Beeper Tone Beeper tones may be programmed directly or incrementally using the following bar c

Pagina 26

28 Power Save Modes and IR Detection The 7600 has five programmable power save modes. Refer to the MetroSelect Programming Guide for additional inf

Pagina 27 - EAS Deactivation Antenna

29 Figure 28: IR Activation Area Parallel to Package Flow Specifications are subject to change without notice.

Pagina 28 - Operation

30 Scan Volume Specifications (BASED ON 100% UPC BAR CODES) Figure 29: Scan Volume in Plane Perpendicular to Flow Figure 30: Scan Volume in Plan

Pagina 29 - Visual Indicators

31 Depth of Field by Minimum Bar Code Element Width (BASED ON 100% UPC BAR CODES) Figure 31: Depth of Field Perpendicular to Flow Minimum Bar

Pagina 30 - Failure Modes

32 Troubleshooting The following guide is for reference purposes only. Contact a customer service representative to preserve the limited warranty t

Pagina 31 - Next Volume

33 SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The unit powers up, but does not scan and/or beep. Scanning a particular symbology that is not enabled. UP

Pagina 32

34 SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Scanner beeps at some bar codes and NOT for others of the same bar code symbology. The bar code may have b

Pagina 33

35 SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Everything works except for a couple of characters. These characters may not be supported by that country’

Pagina 34 - Scan Volume Specifications

ii Limited Warranty ... 50 Regulatory Compliance ...

Pagina 35 - ASED ON 100% UPC BAR CODES)

36 SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Characters are being dropped. Intercharacter delay needs to be added to the transmitted output. Add some i

Pagina 36 - Troubleshooting

37 Design Specifications Operational Light Source: VLD 650 ± 10 nm Laser Power: 1.1 mW maximum Embedded Laser: Max Optical Power: 10 mW Wavelengt

Pagina 37

38 Electrical Input Voltage: 5.2VDC ± 0.25V Power: 2.6 W Operating Current: 500 mA Standby Current: Laser Off Power Save Mode = < 350 mA Lase

Pagina 38

39 Applications and Protocols The model number on each scanner includes the scanner number and factory default communications protocol. Scanner Ver

Pagina 39

40 Default Settings Many functions of the scanner can be "programmed" - that is, enabled or disabled. The scanner is shipped from the fac

Pagina 40 - PN 54-54667]

41 PARAMETER DEFAULT OCIA RS-232 LIGHT PEN RS485 KBW USB Bars High as Scanned  Spaces High as Scanned  DTS/SIEMENS 

Pagina 41 - Design Specifications

42 PARAMETER DEFAULT OCIA RS-232 LIGHT PEN RS485 KBW USB Number of Scan Buffers 1       Transmit EAN-8 Check Digit *     

Pagina 42 - Environmental

43 PARAMETER DEFAULT OCIA RS-232 LIGHT PEN RS485 KBW USB UPC Suffix    Transmit AIM ID Characters    STX Prefix 

Pagina 43 - Applications and Protocols

44 PARAMETER DEFAULT OCIA RS-232 LIGHT PEN RS485 KBW USB Coupon Code 128   as code 39    Programmable Code Lengths 7 avail.  

Pagina 44 - Default Settings

45 Default settings for “Aux” interface The secondary scanner and the 7600 always communicate via RS232. Data is relayed to the host via various p

Pagina 45 - RS485 KBW USB

1 Introduction The Horizon™ 7600 series is Honeywell’s next generation in-counter laser bar code scanner. This compact, hands-free scanner is desig

Pagina 46

46 Scanner and Cable Terminations Scanner Pinout Connections The 7600 scanner interfaces terminate to 10-pin modular jacks located on the back of

Pagina 47

47 Figure 33: Scanner Interface Ports MS762x-37 Keyboard Wedge, Stand-Keyboard or USB MS762x-37 RS-232 or Light Pen Pin Function Pin Function

Pagina 48

48 Cable Connector Configurations (Host End) PowerLink Cable PN 54-54xxx* Pin Function 1 Shield Ground 2 RS-232 Transmit Output 3 RS-232 Receive In

Pagina 49

49 Cable Connector Configuration The PowerLink cable is terminated with a 5-pin DIN female connector on one end, and a 6-pin mini DIN male on the

Pagina 50 - Scanner Pinout Connections

50 Limited Warranty Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in materia

Pagina 51

51 All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unenforceable, such det

Pagina 52

52 Regulatory Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device

Pagina 53

53 Attention L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de graves irradiations. Le client ne doit

Pagina 54 - Limited Warranty

54 Index A Adapter ... 49 Audible ... 24 Autodiscriminates ...

Pagina 55

55 Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please contact us by using one of the m

Pagina 56 - Regulatory Compliance

2 Base Kit Components Part # Description MS7600 Horizon Series Scanner 00-02407 MetroSelect™ Programming Guide 00-02870 Horizon 7600 Installation

Pagina 61

Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-02870 Rev G 12/12

Pagina 62

3 Part # Description AC to DC Power Transformer - Regulated 5.2V@ 1A output 46-46759 120V United States 46-46616 220V – 240V Continental Europea

Pagina 63

4 Scanner Parts Figure 1: Scanner Parts  Output Window (Laser Aperture)  Amber LED (Located Under Window)  Red LED (Located Under Wind

Pagina 64

5 Maintenance Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. Fo

Comentarios a estos manuales

Sin comentarios