Metrologic Stratos MS2xxx Series Guía de usuario

Busca en linea o descarga Guía de usuario para Lectores De Códigos De Barras Metrologic Stratos MS2xxx Series. Metrologic Stratos MS2xxx Series User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
MS2421 / MS2422 / MS2431
Bar Code Scanner
Installation and User’s Guide
Vista de pagina 0
1 2 3 4 5 6 ... 71 72

Indice de contenidos

Pagina 1 - MS2421 / MS2422 / MS2431

MS2421 / MS2422 / MS2431 Bar Code Scanner Installation and User’s Guide

Pagina 2 - Trademarks

6 Electrical Voltage Supply: 4A @ +5V / 0.8A @ +12V Power: Operating: 11.9 Watts Standby: 3.25 Watts Current: Operating: 1.7A @ 5.2V / 0.2A @

Pagina 3 - Table of Contents

7 Base Model Characteristics MS2421/MS2431 Components Figure 5. MS2421/MS2431 Components (MS2421 Shown.) Item No. Description of Item 1 Volu

Pagina 4

8 MS2421 Scanner Dimensions Figure 6. MS2421 Dimensions MS2431 Scanner Dimensions Figure 7. MS2431 Dimensions

Pagina 5 - Introduction

9 MS2421/MS2431Connector Panel Figure 8. MS2421/MS2431 Connector Panel * Scale ready MS2421/MS2431 models supply additional connectors for sca

Pagina 6 - Optional Accessories

10 MS2421/MS2431 Caution and Serial Number Labels Figure 9. MS2421/MS2431 Label Locations (Top) and Examples (Bottom) Caution: To maintain c

Pagina 7 - Replacement Parts

11 MS2422 Components Figure 10. MS2422 Components Item No. Description of Item 1 Volume/Tone Multi-Function Button (see page 42) 2 Blue LED In

Pagina 8 - General Precautions

12 MS2422 Dimensions Figure 11. MS2422 Dimensions MS2422 Connector Panel Figure 12. MS2422 Connectors Specifications are subject to change w

Pagina 9 - Design Specifications

13 MS2422 Caution and Serial Number Labels Figure 13. MS2422 Label Locations (Top) and Examples (Bottom) Caution: To maintain compliance with

Pagina 11 - Base Model Characteristics

15 Installation Quick Installation Outline The following is a quick preview of the steps required for first time installations. Each item is disc

Pagina 12 - MS2431 Scanner Dimensions

Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this documen

Pagina 13

16 Site Requirements Power Installation The Power Supply (AC/DC) should be connected to an AC Outlet that is free of electrical noise (clean). A q

Pagina 14

17 Unpacking the Unit 1. Make sure the shipping box is topside up before opening. 2. Remove the accessories box and check the box’s content for

Pagina 15 - MS2422 Components

18 Installing the Unit in the Counter MS2421 Mounting Diagram Figure 17. MS2421 Mounting Diagram Specifications are subject to change without

Pagina 16 - MS2422 Connector Panel

19 Installing the Unit in the Counter MS2422 Mounting Diagram Figure 18. MS2422 Mounting Diagram Specifications are subject to change without n

Pagina 17

20 Installing the Unit in the Counter MS2431 Mounting Diagram (Two Point Support) Figure 19. MS2431 Mounting Diagram, Two Point Support Specifi

Pagina 18

21 Installing the Unit in the Counter MS2431 Mounting Diagram (Three Point Support) Figure 20. MS2431 Mounting Diagram, Three Point Support Spe

Pagina 19 - Installation

22 Cable Installation (Interface Specific) RS232 The following steps describe how to properly install the cables for an RS232 application. The sc

Pagina 20 - Site Requirements

23 Cable Installation (Interface Specific) RS232 xx** Specifies international connection. See the Base Kit Components and Optional Accessorie

Pagina 21 - Unpacking the Unit

24 Cable Installation (Interface Specific) Full Speed USB The following steps describe how to properly install the cables for a Full Speed USB scan

Pagina 22 - MS2421 Mounting Diagram

25 Cable Installation (Interface Specific) Full Speed USB Step 8 is for USB Serial Emulation Mode or Keyboard Emulation Mode only. 8. Configure t

Pagina 23 - MS2422 Mounting Diagram

iii Table of Contents Introduction Manual Scope ...

Pagina 24

26 Cable Installation (Interface Specific) RS485 The following steps describe how to properly install the cables for an RS485 scanner application.

Pagina 25

27 Cable Installation (Interface Specific) RS485 xx** Specifies international connection. See the Base Kit Components and Optional Accessori

Pagina 26

28 Cable Installation (Secondary Honeywell Scanner) The following steps describe how to properly install the cables between a secondary Honeywell s

Pagina 27

29 Cable Installation (Secondary Honeywell Scanner) † See Aux power notes on page 28 See power source caution statement on pages 10 or 13 of

Pagina 28 - Full Speed USB

30 EAS Deactivation SW1 and SW2 are the switch banks inside the Checkpoint device that set the deactivation range. The following is a list of Check

Pagina 29

31 Scanner Operation Scan Zone Figure 27. Checker-Side (13 mil) Figure 28. Horizontal Left/Right (13 mil) Specifications are subject to change

Pagina 30

32 Scan Zone Figure 29. Horizontal Direct (13 mil) Figure 30. Vertical Direct (13 mil) Specifications are subject to change without notice. Ty

Pagina 31

33 Wake Activation Area (Photocell LED Output) The MS2421/MS2422/MS2431 scanner’s default power save mode† is Dual Action Power Save Mode #2 (see pa

Pagina 32

34 Wake Activation Area Sensitivity (Photocell LED Output Range) Changing the Wake Area Sensitivity Level (Photocell LED Range Adjust) The MS2400 S

Pagina 33 - of this

35 Audible Indicators When in operation, the MS2421/MS2422/MS2431 scanner provides audible feedback that indicates the status of the unit and the

Pagina 34 - EAS Deactivation

iv Scanner Operation Scan Zone ...

Pagina 35 - Scanner Operation

36 Figure 32. Blue LED Visual Indicators Blue LED is located near the bottom corner of the vertical output window. When the scanner is ON, the fl

Pagina 36 - Scan Zone

37 Failure Modes Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsystem failure. The scanner will

Pagina 37 - (Photocell LED Output)

38 Diagnostic Indicator Display There is a two-digit error code display located under horizontal output window near the top of the platter (see fig

Pagina 38 - ³ 2 2 1 2 3 0

39 Error Code Description 09 COPROCESSOR COMMUNICATION ERROR – The main microprocessor is not communicating with the interface coprocessor. The in

Pagina 39 - Audible Indicators

40 Error Code Description 28 LASER #2 (RIGHT HORIZONTAL) UNDERCURRENT WARNING – The laser in the right horizontal scanning subsystem is drawing to

Pagina 40 - Visual Indicators

41 Power Save Modes The MS2421/MS2422/MS2431 bar code scanners have five configurable power save modes. Refer to the MetroSelect Configuration Gui

Pagina 41 - Failure Modes

42 Beeper Options and Button Functions Changing the Beeper Tone Beeper tones may be configured incrementally using the following bar code. The new

Pagina 42

43 Startup When the scanner first receives power, the blue LED will turn on and the scanner will beep once. The scanner is now ready to scan. Power

Pagina 44

45 Maintenance Horizontal Scan Window Replacement Note: After the replacement platter has been installed, remove all protective film from the ne

Pagina 45 - Power Save Modes

1 Introduction Manual Scope This guide provides information on the installation, setup and operation of the MS2421, MS2422, and MS2431 scanner onl

Pagina 46 - The Multi-Function Button

46 Daily Maintenance Smudges and dirt on the unit’s window can interfere with the unit’s performance. If the horizontal or vertical output windows

Pagina 47 - Configuration Mode

47 Troubleshooting The following guide is for reference purposes only. Contact a customer service representative to preserve the limited warranty

Pagina 48

48 Symptom Possible Cause(s) Solution All Interfaces Scanner beeps at some bar codes and NOT for others of the same bar code symbology. The print

Pagina 49 - Maintenance

49 Symptom Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanner and host may not be c

Pagina 51 - Troubleshooting

51 Scanner and Cable Terminations Scanner Pinout Connections The MS2421/MS2422/MS2431 scanner terminates to 10-pin modular jacks located on the bo

Pagina 52

52 Scale Ready MS2421/MS2431 Models – Additional Pinout Connections There are four additional 10-pin modular jacks located on the bottom of the of t

Pagina 53

53 Cable Connector Configurations The following cables are examples of some of the standard cables that may be shipped with the MS2421/MS2422/MS243

Pagina 54

54 Cable Connector Configurations Aux Port Configuration Cable*, PN 57-57008x-N-3 Pin Function** 9-Pin D-Type Connector 1 No Connect 2 Output fro

Pagina 55 - Scanner Pinout Connections

55 Regulatory Compliance Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution

Pagina 56

2 Base Kit Components Part # Description MS24xy-105Nz Bar Code Scanner x 2 MS2420 3 MS2430; 508 mm (20.0") y 1 Scanner Only, Scale Ready

Pagina 57

56 EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Note: Immunity performance is not guaranteed for scanner

Pagina 58

57 Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare interferenze radio ch

Pagina 60 - European Standard

59 Limited Warranty Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in mate

Pagina 62

61 Patents For patent information, please refer to www.honeywellaidc.com/patents.

Pagina 64

63 Index A AC ... see power application ...

Pagina 65 - Patents

64 R razzberry tone ... 35, 36, 37 regulatory compliance ... 55–56 repair ...

Pagina 66

65 Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nea

Pagina 67

3 Optional Accessories Part # Description AC to DC Power Transformer - Regulated Output: +5V @ 3.8A +12V @ 0.8A 46-00980-R 120V United States a

Pagina 68

66 Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To

Pagina 70 - Product Service and Repair

Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-05311 Rev E 4/11

Pagina 71

4 General Precautions The following are some general precautions to remember when handling the MS2421/MS2422/MS2431 scanner. Do not turn the u

Pagina 72

5 Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: <1.5 mW Horizontal Depth of Field: 0 mm - 100 mm (0"- 4&

Comentarios a estos manuales

Sin comentarios