53
Cable Connector Configurations
The following cables are examples of some of the standard cables that may be shipped with the
MS2421/MS2422/MS2431 bar code scanner. Please keep in mind that every application is unique and the
cables received with the MS2421/MS2422/MS2431 scanner may be custom cables that are not shown
below.
RS232 Interface Cable, PN 57-57210x-N-3
Pin
Function**
9-Pin D-Type Connector
1
No Connect
2
RS232 TX Output
3
RS232 RX Input
4
DTR Input
5
Power/Signal Ground
6
DSR Output
7
CTS Input
8
RTS Output
9
No Connect
Full Speed USB Cable,
PN 57-57201x-N-3 or PN 57-57227x-N-3
Pin
Function**
Locking, Type A
57-57227x-N-3
Non-Locking, Type A
57-57201x-N-3
1
PC+5V USB
2 Data -
3
Data +
4
Ground
RS485 Cable, PN 57-57212x-N-3
Pin
Function**
4-Pin SDL
1 Signal Ground
2
IBM A+
3
IBM B -
4
No Connect
** All signals are referenced from the MS2421/MS2422/MS2431 scanner.