Metrologic StratosS MS2220 Guía de usuario Pagina 75

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 88
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 74
69
SCANNER AND CABLE TERMINATIONS
SCANNER PINOUT CONNECTIONS
The MS2220 Series scanner interfaces terminate to 10-pin modular jacks located on the bottom of the units. The serial
number label indicates the model number of the scanner.
Figure 69. Connector Layout
EAS
Auxiliary RS232 In
DC Power
Pin Function
Pin Function
Pin Function
1 EAS In
1 Ground
1 12VDC
2 EAS Out
2 RS232 Receive Input
2 Ground
3 RS232 Transmit Output
3 5.2VDC
4 RS232 RTS In
5 RS232 CTS Out
6
No Connect
7
No Connect
8
No Connect
9 +5V Out
10
No Connect
Scale RS232 to Host
(Scale Data, Dual Cable Applications)
Scale to Display
Pin Function
Pin Function
1 Ground 1 SIG1
2 Scale RS232 TX Out 2 SIG2
3 Scale RS232 RX In 3 SIG3
4 Scale RS232 RTS Out 4 SIG4
5 Scale RS232 CTS In 5 SIG5
6
No Connect
6 SIG6
7
No Connect
7 SIG7
8
No Connect
8 SIG8
9
No Connect
9 SIG9
10 Shield 10 SIG10
Specifications are subject to change without notice.