Metrologic IS1000 Series Guía de usuario Pagina 124

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 198
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 123
118
CipherLab BASIC Compiler
User's Guide
Return
@TMbbtt…\r (tt repeat)
bb: Base ID (01 ~ 16)
tt: Terminal ID (01 ~ 45)
Transmission Timeout: @TO RF Base
Purpose
To set or get the timeout setting.
Syntax
@TObbtt\r
bb: Base ID (01 ~ 16)
tt: Timeout setting (01 ~ 99 sec); set 00 to get the current timeout.
Return
@TObbttTT\r
bb: Base ID (01 ~ 16)
tt: Original timeout (01 ~ 99 sec)
TT: New timeout (01 ~ 99 sec)
Update Program: @UP RF Base
Purpose
To enter the download mode for updating the Base program.
Syntax
@UPbb\r
bb: Base ID (01 ~ 16)
Return
@UPbb\r
bb: Base ID (01 ~ 16)
The Base is ready for downloading new program after returning this message.