172
CipherLab BASIC Compiler
User's Guide
EAN13 & UPCA
ISBN Conversion
If this parameter is enabled, the EAN 13 codes starting with 978 and 979
will be converted to ISBN code.
ISSN Conversion
If this parameter is enabled, the EAN 13 codes starting with 977 will be
converted to ISSN code.
Transmit Checksum
If this parameter is enabled, the EAN 13 checksum character will be
included in the data being transmitted.
Transmit UPCA System
Number
If this parameter is enabled, the UPCA system number will be included in
the data being transmitted.
Transmit UPCA Checksum
If this parameter is enabled, the UPCA checksum character will be
included in the data being transmitted.
MSI
Checksum Verification
User can select one of the three kinds of checksum calculations, i.e.,
Single Modulo 10, Double Modulo 10, and Modulo 11 & 10, to verify
MSI code. If the checksum character is incorrect, the barcode will not be
read.
Checksum Transmission
This parameter specifies how the checksum is to be transmitted. User can
select from “Last digit not transmitted”, “Transmitted”, and “Last 2 digits
not transmitted”.
Length Qualification
Because of the weak structure of the MSI code, it is possible to make a
"short scan" error. To prevent the "short scan" error, user can define the
"Length Qualification" settings to insure that the correct code is read by
qualifying the allowable code length. The barcode can be qualified by
"Fixed Length" or "Max/Min Length". If "Fixed Length" is selected, up
to 2 fixed lengths can be specified. If "Max/Min Length" is selected, the
maximum length and the minimum length must be specified. The target
terminal will only accept MSI code with lengths that fall between
max/min lengths specified.
Plessey
Convert to UK Plessey
If this parameter is enabled, the target terminal will change each
occurrence of the character 'A' to character 'X' in the code.